BT

The Good Scents Company Information Listings

This page contains the EPI System Summary only.
For complete control of this information -
Download the free EPI SuiteTM v4.0 program : here
also you can go back to the Datasheet

CAS Number: 5682-69-9

SMILES : O=C1C=C(CC)CC1

CHEM :

MOL FOR: C7 H10 O1

MOL WT : 110.16

------------------------------ EPI SUMMARY (v4.10) --------------------------

Physical Property Inputs:

Log Kow (octanol-water): ------

Boiling Point (deg C) : ------

Melting Point (deg C) : ------

Vapor Pressure (mm Hg) : ------

Water Solubility (mg/L): ------

Henry LC (atm-m3/mole) : ------

Log Octanol-Water Partition Coef (SRC):

Log Kow (KOWWIN v1.68 estimate) = 1.75

Boiling Pt, Melting Pt, Vapor Pressure Estimations (MPBPVP v1.43):

Boiling Pt (deg C): 175.42 (Adapted Stein & Brown method)

Melting Pt (deg C): -9.55 (Mean or Weighted MP)

VP(mm Hg,25 deg C): 1.63 (Mean VP of Antoine & Grain methods)

VP (Pa, 25 deg C) : 218 (Mean VP of Antoine & Grain methods)

Water Solubility Estimate from Log Kow (WSKOW v1.42):

Water Solubility at 25 deg C (mg/L): 3502

log Kow used: 1.75 (estimated)

no-melting pt equation used

Water Sol Estimate from Fragments:

Wat Sol (v1.01 est) = 1420.4 mg/L

ECOSAR Class Program (ECOSAR v1.00):

Class(es) found:

Vinyl/Allyl Ketones

Henrys Law Constant (25 deg C) [HENRYWIN v3.20]:

Bond Method : 3.76E-005 atm-m3/mole (3.81E+000 Pa-m3/mole)

Group Method: 4.66E-006 atm-m3/mole (4.72E-001 Pa-m3/mole)

For Henry LC Comparison Purposes:

User-Entered Henry LC: not entered

Henrys LC [via VP/WSol estimate using User-Entered or Estimated values]:

HLC: 6.747E-005 atm-m3/mole (6.836E+000 Pa-m3/mole)

VP: 1.63 mm Hg (source: MPBPVP)

WS: 3.5E+003 mg/L (source: WSKOWWIN)

Log Octanol-Air Partition Coefficient (25 deg C) [KOAWIN v1.10]:

Log Kow used: 1.75 (KowWin est)

Log Kaw used: -2.813 (HenryWin est)

Log Koa (KOAWIN v1.10 estimate): 4.563

Log Koa (experimental database): None

Probability of Rapid Biodegradation (BIOWIN v4.10):

Biowin1 (Linear Model) : 0.7019

Biowin2 (Non-Linear Model) : 0.7294

Expert Survey Biodegradation Results:

Biowin3 (Ultimate Survey Model): 2.9333 (weeks )

Biowin4 (Primary Survey Model) : 3.6666 (days-weeks )

MITI Biodegradation Probability:

Biowin5 (MITI Linear Model) : 0.5976

Biowin6 (MITI Non-Linear Model): 0.7557

Anaerobic Biodegradation Probability:

Biowin7 (Anaerobic Linear Model): 0.0771

Ready Biodegradability Prediction: YES

Hydrocarbon Biodegradation (BioHCwin v1.01):

Structure incompatible with current estimation method!

Sorption to aerosols (25 Dec C)[AEROWIN v1.00]:

Vapor pressure (liquid/subcooled): 199 Pa (1.49 mm Hg)

Log Koa (Koawin est ): 4.563

Kp (particle/gas partition coef. (m3/ug)):

Mackay model : 1.51E-008

Octanol/air (Koa) model: 8.97E-009

Fraction sorbed to airborne particulates (phi):

Junge-Pankow model : 5.45E-007

Mackay model : 1.21E-006

Octanol/air (Koa) model: 7.18E-007

Atmospheric Oxidation (25 deg C) [AopWin v1.92]:

Hydroxyl Radicals Reaction:

OVERALL OH Rate Constant = 82.1940 E-12 cm3/molecule-sec

Half-Life = 0.130 Days (12-hr day; 1.5E6 OH/cm3)

Half-Life = 1.562 Hrs

Ozone Reaction:

OVERALL Ozone Rate Constant = 7.393750 E-17 cm3/molecule-sec

Half-Life = 0.155 Days (at 7E11 mol/cm3)

Half-Life = 3.720 Hrs

Fraction sorbed to airborne particulates (phi):

8.77E-007 (Junge-Pankow, Mackay avg)

7.18E-007 (Koa method)

Note: the sorbed fraction may be resistant to atmospheric oxidation

Soil Adsorption Coefficient (KOCWIN v2.00):

Koc : 29.18 L/kg (MCI method)

Log Koc: 1.465 (MCI method)

Koc : 122.7 L/kg (Kow method)

Log Koc: 2.089 (Kow method)

Aqueous Base/Acid-Catalyzed Hydrolysis (25 deg C) [HYDROWIN v2.00]:

Rate constants can NOT be estimated for this structure!

Bioaccumulation Estimates (BCFBAF v3.01):

Log BCF from regression-based method = 0.820 (BCF = 6.6 L/kg wet-wt)

Log Biotransformation Half-life (HL) = -0.9021 days (HL = 0.1253 days)

Log BCF Arnot-Gobas method (upper trophic) = 0.736 (BCF = 5.447)

Log BAF Arnot-Gobas method (upper trophic) = 0.736 (BAF = 5.447)

log Kow used: 1.75 (estimated)

Volatilization from Water:

Henry LC: 4.66E-006 atm-m3/mole (estimated by Group SAR Method)

Half-Life from Model River: 132.9 hours (5.539 days)

Half-Life from Model Lake : 1538 hours (64.09 days)

Removal In Wastewater Treatment:

Total removal: 2.33 percent

Total biodegradation: 0.09 percent

Total sludge adsorption: 1.97 percent

Total to Air: 0.26 percent

(using 10000 hr Bio P,A,S)

Level III Fugacity Model:

Mass Amount Half-Life Emissions

(percent) (hr) (kg/hr)

Air 0.215 1.7 1000

Water 33.9 360 1000

Soil 65.8 720 1000

Sediment 0.103 3.24e+003 0

Persistence Time: 396 hr

Top of Page Home
Copyright © 1980-2021 The Good Scents Company (tgsc) Disclaimer Privacy Policy